LCT LAS-AX1/ Tension/Compression Load cell/ S- beam/ IP65/ Aluminum / for crane scale
Description
Model: LAS-AX1
Brand: LCT
Capacity: 10,20,30,50,100 (KG)
Usage: Mainly used for crane scale,hopper scale,tension control,tensile testing etc.
Dimension: 50.8*50.8*18MM
分享
描述
Description
Model: LAS-AX1
Brand: LCT
Capacity: 10,20,30,50,100 (KG)
Usage: Mainly used for crane scale,hopper scale,tension control,tensile testing etc.
Dimension: 50.8*50.8*18MM
Features
- S-type load cells
- capacity:10kg,...,100kg
- accuracy:0.05% R.O.
- low cost
- aluminum construction with surface anodized
- environment protection class:IP65
Applications
- crane scales
- hopper scales
- tensile testing
- test benches
- machine testing
Description
LCT S-type Load Cells have been designed for measuring static and dynamic tensile and compressive forces.
Advantages of LCT S-type Load Cells:
Quick to install thanks to off-center load compensation at the factory (per OIML R60),and you benefit from a new generation of high-precision, S-type load cells. Be it force measurement in machines, test benches and production lines or tests in development: LCT S-type load cells are the reliable and safe choice for precise force measurement - providing compelling benefits for you.
Model LAS-AX1 load cells are designed to this “S-type”and manufactured from high quality aluminum alloy of aviation standard. LAS-AX1 load cells can be used to measure loads range from 10kg to 100kg with the measuring accuracy of 0.05% R.O.( R.O.=Rated Output) and 2mV/V output signal.
LAS-AX1 load cells are mainly used for crane scales,hopper scales,tensile testing,test benches and machine testing.

Electrical Connection


Technical Data
Note
Rated Capacity | 10, 20, 30, 50, 100 (kg) |
Accuracy Class | S |
Rated Output | 2.0 ± 10%mV/V |
Zero Balance | ±5%R.O. |
Input Resistance | 1130±20Ω |
Output Resistance | 1000±10Ω |
Linearlty Error | ±0.05%R.O. |
Repeatability Error | ±0.05%R.O. |
Hysteresis Error | ±0.05%R.O. |
Creep in 30 Min. | ±0.05%R.O. |
Temp.Effect on Output | ±0.05%R.O./10℃ |
Temp.Effect on Zero | ±2%R.O./10℃ |
Compensated Temp.Range | 0-+40℃ |
Excitation,Recommended | 3-5VDC |
Excitation,Maximum | 6VDC |
Operating Temp.Range | -10-+40℃ |
Safe Overload | 150%R.C. |
Ultimate Overload | 200%R.C. |
Insulation Resistance | ≥2000MΩ(50VDC) |
Cable,Length | ø0.8mm× 0.1m * |
Protection Class | IP65 |
Note
- The length of cable can be customized.